  • Vertical SVG
Medium/low Voltage Electric Power Quality Correction Equipment

Vertical SVG

The basic principle of SVG (Static Var Generator, also known as STATCOM) is to parallel self...

  • Product Introduction
  • Product Features
  • Technical Parameters

Product Introduction

The basic principle of SVG (Static Var Generator, also known as STATCOM) is to parallel self-commutated bridge circuit with the power grid through reactor or transformer. Through the proper regulation of phase and amplitude of bridge circuit AC output voltage, or the direct control of current, the device makes the circuit absorb or deliver the qualified reactive current, and then achieve the purpose of dynamic reactive power compensation.


Product Features

  • Fast Response Speed

    SVG response time: ≤5ms

    SVG can complete the mutual conversion from rated capacitive reactive power to rated inductive reactive power in a very short time, and be competent for the impact load compensation.

High Security

SVG is controlled as the current source during the operation, so there is no possibility of resonance with the system impedance.

  • Diversified Compensation Functions

    The single SVG device has the following functions:

    Load reactive compensation;

    Load harmonics compensation;

    Load unbalance compensation;

    Load reactive, harmonic and unbalance compensation at the same time.

  • Low Harmonic Content

    The carrier phase-shifting modulation technology is adopted to achieve high frequency low pulse and low harmonic content of output current.

  • Small Floor Area

    PWM reactive power compensation, no parallel capacitor with large-capacity, small floor area.


Technical Parameters

AC Input

Rated Voltage

6kV/10kV/35kV

Rated Frequency

50x (1±5%) Hz

Connection Mode

Three-phase three-wire

Target Power Factor

Meet the set requirements within the capacity range

Response Time

5 ms

Active Power Loss

<0.8% rated power

Ambient Conditions

Operating Temperature

-10°0+45°C

Storage Temperature

-20°0+65°C

Relative Humidity

<90% (at 25°C)

Operating Mode

Constant Power Factor, constant reactive power, constant voltage control are optional

Communication Interface

Remote RS485,upper computer communication software are optional

Operation Display

Operation parameter set, touchable key operation, multi-parameter display, operation parameter record, fault recording, parameter & record data backup, remote control and parameter download

Display Precision

±2%FS

Expansion Capability

Parallel operation meets the requirements of larger capacity occasion

Protection

Overvoltage, under-voltage, default phase, over current, overheating, DC bus-bar over & under voltage, overload automatic current limit protection, power supply abnormal protection control, communication fault protection, controller abnormal protection, control system power-off protection